ABB AB, High Power Laboratory

Lyviksvägen 14, SE-771 80 Ludvika, SWEDEN

Website

+46 240 782 606

Address: Lyviksvägen 14, SE-771 80 Ludvika, SWEDEN
Telephone: (46) 240 782 606   Telefax: (46) 240 782 619
E-Mail: highpowerlab@se.abb.com
Key Contact Personnel:
Johan Lidholm, Laboratory Manager johan.lidholm@se.abb.com
Tomas Bergström, Marketing Manager tomas.bergstrom@se.abb.com
Year Founded: HP Lab: 1933
Total Number of Employees: 43
Major Export Markets Served (2016): Asia, Middle East, Europe, USA


High Power Laboratory

Total Number of Employees in HP Laboratory: 39
Kind of Power Source for the HP Laboratory: Two short circuit generators
Specifications of Main Test Bay:
Dimension of Main Test Hall: Two high-voltage test cells, 24 m x 15 m x 17 m
Dimension of Secondary Test Hall: Seven medium-voltage test cells Synthetic Installation: Two circuits, ±880 kV, main capacitor bank 6.7 MJ, parallel-current injection/voltage-injection, 4- parameter TRV, a.c. recovery voltage; Three-phase synthetic testing; Synthetic capacitive-current switching. Synthetic making tests up to 550 kV full-pole
Possible Power Frequency: from 16 2/3 to 60 Hz
Max. kV in Test Bay from Synthetic Installation: 1100 kVp; 550 kV / 80 kA (full pole), single-phase testing & 245 kV / 63 kA, three-phase testing
Electrical Tests:
Medium Voltage Tests:
Short circuit making & breaking tests, capacitive current switching tests, internal-arc tests, pressure-relief tests, power-arc tests, bus-transfer switching tests, induced-current switching tests; short-circuit withstand tests on transformers, current transformers, disconnectors, reactors, line-traps; breaking capacity & service-duty tests on on-load tap-changers
High Voltage Tests:
Terminal-fault, short-line fault, out-of-phase switching, line-charging switching, cable-charging switching, single capacitor bank switching & shunt reactor switching tests on HV circuit breakers up to 800 kV rating, short circuit withstand test on power transformers
Heat Run Tests: 25 kA max. continuous current at 50 & 60 Hz
Mechanical testing:
Dimension of test hall: 16 m x 13 m x 22 m
Dimension of secondary test halls: 1 1 m x 7 m x 15 m
Type Testing of High voltage and Medium Voltage Equipment according to international product standards (IEC, IEEE).
Others: Mechanical cycling test, cantilever test, pull tests.
Climate chamber 1.0 x 1.6 x 0.9 m (-70 …+180), Quantifying gas leakage rate of products.
Surge Arrester Tests:
Testing of HV and MV Surge Arresters. Thermal, TOV, Power Frequency, Mechanical load and Short Circuit tests.

 

Posted in Electrical Tests, Heat Run Tests, High Power Laboratory, Mechanical Tests, Other Test Laboratories and Other Types of HP Tests

Reviews are disabled, but trackbacks and pingbacks are open.

Related Listings

Les Renardières

+33 1 60 73 62 00

F-77818 Moret Loing et Orvanne Cedex, FRANCE

Telefax: +33 1 60 73 69 56 Key Contact Personnel: Laboratory Development Manager  franck.aragnou@edf.fr Head of HP Laboratory  alexandre.zenerino@edf.fr Head of HV Laboratory  emmanuel.bic@edf. Read More

IEN

+48 22 836 80 48

Street Mory 8, 01-330 Warsaw, POLAND

High Voltage Laboratory: Telefax: +48 22 836 80 48 High Power Laboratory: Telephone: +48 22 836 73 35, +48 22 3451386 Telefax: +48 22 836 73 35 E-Mail: eur@ien.com.pl, ewp@ien.com. Read More